Tag Archives: safety gates

Pedestrian Traffic Control Signs Mounted on Gates

While our Mezzanine Stair and Ladder Gates (MLG safety gates) are designed to meet OSHA fall protection requirements, they also work great as pedestrian traffic control gates. Below you can see that the design lends itself very easily to control pedestrian traffic flow to restricted locations. They are also a great way to get your message out. 

304 stainless steel MLG gate used for pedestrian traffic control with mounted signage

304 stainless steel MLG gate used for pedestrian traffic control with mounted signage

Your Message… Right Where You Need It

Our customer above had custom signs printed up that they riveted onto our stainless steel gate. After mounting the sign to our MLG gate, their message is front and center – right where they need it. Do you have cost concerns about using these at your location? It is easy to incorporate an advertisement for a local business with its logo/slogan to offset the cost of the gate and sign printing. While A-Mezz does not offer graphic printing, we have heard from customers that they have had it done for $30-100 per sign – depending on what material and options they choose, such as di-cutting they had selected from their printer. 

Rear view of MLG 304 stainless steel safety gate mounted to stairs with pedestrian traffic control sign.

Rear view of MLG 304 stainless steel safety gate mounted to stairs with pedestrian traffic control sign.

MLG gates are also a great place to have important safety information such as at the top of a ladder that accesses a confined space.

Stairwell Interruption Gate

Our MLG gates are also often used to comply with NFPA 101 – Life Safety Code as a stairwell interruption gate. The 2018 edition of NFPA 101 stipulates 7.7.3.2: “Stairs and ramps that continue more than one-half story below the level of discharge shall be provided with an approved means to prevent or dissuade occupants from traveling past the level of discharge during emergency building evacuation”

When descending a stairway, A-Mezz MLG gates are used where the stairs continue past the emergency exit. The gates stop panicked occupants from continuing down the stairs, past the exit point.  When ascending the stairs from below, anyone can simply walk through the gate to safety. Many customers have aluminum signs printed stating there is no exit past the gate and an arrow pointing to the exit location. 

While they were designed for fall protection applications, our MLG gates are much more versatile. Featuring quick shipping times, in-stock status, and low cost, MLG gates are ideal for many uses. Contact A-Mezz today for more details and a quote.

Do I Need a Swing Gate on My Fixed Ladder?

 

Walk-thru fixed ladder with cage

Walk-thru fixed ladder with safety cage

Do you need a ladder gate at your ladder opening in your railing? According to OSHA 1910.28(b)(3)(iv)“Each employee is protected from falling into a ladderway floor hole or ladderway platform hole by a guardrail system and toeboards erected on all exposed sides, except at the entrance to the hole, where a self-closing gate or an offset must be used.”

This means that every ladder opening needs to be either (a) Offset so that a person cannot walk (or fall) directly into the opening or (b) Protected by a ladder safety gate. It is an easy either/or. The most common ladder installation locations are not offset and as such require safety gates. Below you will see some photos of ladders and top view sketches clarifying why each of their orientations either do or do not require a gate. Note: ladder chains do not meet OSHA standards.

Another seemingly redundant standard from OSHA further increases the areas requiring gates is 1910.29(b)(13) and 1910.29(b)(13)(i): When guardrail systems are used around holes that serve as points of access (such as ladderways), the guardrail system opening: (1910.29(b)(13)(i) has a self closing gate that slides or swings away from the hole, and is equipped with a top rail and midrail or equivalent intermediate member(…). 

This standard opens up gate requirements to manhole covers, roof hatches and other similar systems that would remain open while accessed.

Now that we know what the code requirement is, it is time to review a few common ladder mounting orientations to discuss where they fall under the code.

Fixed ladder mounted to side of platform

Fixed ladder mounted to side of platform

The above fixed ladder is mounted onto the side of the platform. Work is performed further down the platform but it is possible to fall directly down the ladder opening. This location is not offset and as such would require a swing gate. See the below top view sketch for clarification.

Top view sketch of side mounted fixed ladderway opening

Top view sketch of side mounted fixed ladderway opening

You can walk directly to the ladder opening from where work is/can be expected to be performed and as such, a safety gate is required at the ladder opening.

Fixed ladder with offset landing platform

Fixed ladder with offset landing platform

The above ladder accesses a platform and then turns to access the main walkway. This ladder is offset and would not require a swing gate at the opening.

Top view sketch of offset mounted fixed ladderway opening

Top view sketch of offset mounted fixed ladderway opening

As you can see above, if someone fell while at the main walkway they would fall onto the ladder landing surface, they would not fall down the ladder opening. If the ladder was rotated to the left side of the landing it would require a safety gate because then the ladder opening would no longer be offset.

Ladderway opening on side of catwalk

Ladderway opening on side of catwalk

Above is a very common ladder mount position. This one can be tricky until you lay it out from the top view. From first glance it looks like because the ladder is off to the side that it would be offset from the normal flow of traffic, but if you fell at that point of the catwalk there would be no guarding to protect you. A swing gate is a requirement at this location.

Top view sketch of catwalk side mounted fixed ladderway opening

Top view sketch of catwalk side mounted fixed ladderway opening

As you can see from the above sketch, there is a single direction of travel to the ladder from the catwalk. This is not offset. It would be a single direction fall into the ladder opening and as such, a ladder safety gate is required to protect your employees when a ladder is installed in the above orientation.

Most areas are not offset. A good rule of thumb is that if you can fall into the ladder opening with a single direction fall, then you are not offset. The only example above that didn’t need a gate was the second ladder location. With that orientation, you would fall onto the ladder landing and then hit the rear railing, not fall through the ladder opening.

Replacement Stair Rails

We recently were called out to a site with a corrosive environment that was in need of replacement stair rails as all of the original handrails were rusting and in disrepair. The paint was almost all chipped up, and some areas of the handrails were so corroded you had to choose between risking a fall by not grabbing the stair handrails, and grabbing the handrails but risking the need for a tetanus shot.

Existing railings corroded from damp environment

Existing railings corroded from damp environment

The above picture shows the lowest section with a bollard and chain assembly “protecting” the pit ladder that is bent, corroded and weakened at the base. It also doesn’t meet OSHA standards for rail heights or strength at top rail. You can also see the rusted handrail and stair rail. Anytime you have a damp environment it’s best to use a material besides carbon steel – Galvanized steel, aluminum or stainless steel all perform much better over time. Remember that corrosion doesn’t just make the metals look bad, but it also weakens them, substantially lessening their lifetime usability. Sure, the other metal options cost more than plain carbon steel, but when you have to replace the material before its time you have to pay for demo of the inferior material, fabrication of the new material, installation of the new material and have the lost time from the job being out of service during that process.

 

New hot dipped galvanized replacement stair rails and safety gate

New replacement hot dipped galvanized railings and safety gate

Here is the same view after we finished. We removed the bollard and replaced it with one with a more sturdy post and baseplate. The chains were removed and replaced with our MLG Ladder Safety Gate with a hot dipped galvanized finish. The new set-up is going to stand up to the moist, caustic environment much better and easily meets OSHA standards for guarding at a ladderway opening.

29 CFR 1910.23 Guarding of floor and wall openings and holes. “(a)(2) Every ladderway floor opening or platform shall be guarded by a standard railing with standard toe board on all exposed sides (except at entrance to opening), with passage through the railing either provided with a swing gate or so offset that a person cannot walk directly into the opening.”

New rails with OSHA required toe guard to prevent items from falling over the edge

New rails with OSHA required toe guard to prevent items from falling over the edge

All of the new handrails were done to OSHA standards with a 4” toe kick at the bottom, a 21” mid rail and a 42” top rail. Along the stairs, the stair rails were 34” high from the edge of the nosing. There was no wall mounted rail as the stair width is less than 44” wide and there is only one open side.

29 CFR 1910.23 (d) Stairway railings and guards. “(1)(ii) On stairways less than 44 inches wide having one side open, at least one stair railing on open side.”

 

Smooth, continuous handrail to maintain contact with rail throughout the climb

Smooth, continuous handrail to maintain contact with rail throughout the climb

The replacement stair rails are designed for a seamless transition between flights, allowing someone to slide their hand from the top rail to the bottom of the stairs without letting go of the rail. This gives a nice, clean look and also allows for safer access and increased strength of rails. Added strength also comes from the baseplate design with a four bolt pattern to maximize rail strength and minimize movement regardless of where pressure is applied front, back, top etc.

There were some unique challenges to this project with the winding rails, but with proper site dimensions and knowing the details about the installation environment, it was quite easy to supply this customer with replacement rails that fit and will last them a lot longer than their previous set.